Mediloop
WORKSTATION AGENT

Workstation Agent — Connector Management

7 of 12

Install, configure, isolate, monitor, update and remove local connector runtimes managed by the Workstation Agent.

ModularIsolatedHot-ReloadableSelf-ContainedUpdatable
Connector runtime model
Mediloop Web Application
Secure channel
WSS / gRPC TLS
Workstation Agent (Core)
Connector Manager
Security & Permissions
Routing & Multiplexing
Event Bus
Logging & Diagnostics
Connector (e.g. Dictation)
Connector (e.g. LIS Analyzer)
Connector (e.g. Smart Card)
Connector (e.g. DICOM Store)
Connector (Custom …)
Protocol / Driver
(specific)
USB / HID Devices
Serial / COM Devices
Smart Card Readers
Local Applications
File System
Legacy Systems
Each connector runs in its own isolated process with least-privilege access to only the resources it needs.
Connector lifecycle
Discover available connectors
Install verified package
Enable for tenant/workstation
Configure resources and settings
Run and connect to local resources
Monitor health and events
Update, disable or remove safely
Installed connectors
5
Installed
4
Running
1
Stopped
0
Error
ConnectorVersionStatusResourcesLast activity
Dictation Microphone2.3.1Running2 devices10:21:34
Speech-to-Text Engine2.1.0RunningLocal service10:21:30
Smart Card (CPS/eID)1.9.4Running1 reader10:21:28
LIS Analyzer3.0.2RunningCOM310:20:11
DICOM Store (Orthanc)1.8.0StoppedPort 8042
Legacy Printer Bridge1.4.2Disabled1 printer
Connector details
NameDictation Microphone
Version2.3.1
PublisherMediloop S.A.
TypeDevice Connector
ResourcesPlantronics DA80, Olympus RS-31H
Permissionsmicrophone.capture, audio.stream
Uptime3h 22m 12s
Configuration
Resource binding
Connector-specific settings
Network / ports
Logging, retries and buffers
Process isolation
Separate OS process per connector
Crash does not affect others
Memory and CPU limits
Standard I/O captured and logged
Automatic restart on failure
Health & monitoring
Real-time status and checks
Heartbeat to Agent
Event and performance metrics
Automatic alerts on failure
jsonCopy
{
 "connector":"dictation-mic",
 "status":"healthy",
 "uptime":12353,
 "errors":1
}
Updates, rollback & removal
Automatic or manual update
Compatibility enforcement
Rollback to previous version
Safe removal and cleanup